Search Results (2364 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-40760 1 Siemens 1 Altair Grid Engine 2026-04-15 5.5 Medium
A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly handle error messages and discloses sensitive password hash information when processing user authentication requests. This could allow a local attacker to extract password hashes for privileged accounts, which can then be subjected to offline brute-force attacks.
CVE-2023-32735 1 Siemens 11 Simatic Step 7, Simatic Step 7 Safety, Simatic Wincc and 8 more 2026-04-15 6.5 Medium
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-40771 1 Siemens 6 Simatic Cp 1542sp-1, Simatic Cp 1542sp-1 Irc, Simatic Cp 1543sp-1 and 3 more 2026-04-15 9.8 Critical
A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data.
CVE-2023-50821 1 Siemens 3 Simatic Pcs 7, Simatic Wincc, Simatic Wincc Runtime Professional 2026-04-15 6.2 Medium
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 1), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly validate the input provided in the login dialog box. An attacker could leverage this vulnerability to cause a persistent denial of service condition.
CVE-2025-40743 1 Siemens 4 Sinumerik 828d, Sinumerik 840d Sl, Sinumerik Mc and 1 more 2026-04-15 8.3 High
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.
CVE-2025-40587 1 Siemens 1 Polarion 2026-04-15 7.6 High
A vulnerability has been identified in Polarion V2404 (All versions < V2404.5), Polarion V2410 (All versions < V2410.2). The affected application allows arbitrary JavaScript code be included in document titles. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by creating specially crafted document titles that are later viewed by other users of the application.
CVE-2025-40804 1 Siemens 1 Simatic 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC Virtualization as a Service (SIVaaS) (All versions). The affected application exposes a network share without any authentication. This could allow an attacker to access or alter sensitive data without proper authorization.
CVE-2025-40763 1 Siemens 1 Altair Grid Engine 2026-04-15 7.8 High
A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly validate environment variables when loading shared libraries, allowing path hijacking through malicious library substitution. This could allow a local attacker to execute arbitrary code with superuser privileges by manipulating the environment variable and placing a malicious library in the controlled path.
CVE-2023-52238 1 Siemens 2 Ruggedcom Rst2228, Ruggedcom Rst2228p 2026-04-15 4.3 Medium
A vulnerability has been identified in RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0). The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.
CVE-2024-35292 1 Siemens 10 Simatic S7-200 Smart Cpu Cr40, Simatic S7-200 Smart Cpu Cr60, Simatic S7-200 Smart Cpu Sr20 and 7 more 2026-04-15 8.2 High
A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices are using a predictable IP ID sequence number. This leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition.
CVE-2024-32010 1 Siemens 1 Spectrum Power 4 2026-04-15 7.8 High
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to extraction of database credentials via a world-readable credential file. This allows an attacker to connect to the database as privileged application user and to run system commands via the database.
CVE-2024-32008 1 Siemens 1 Spectrum Power 4 2026-04-15 7.8 High
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to an exposed debug interface on the localhost. This allows any local user to gain code execution as administrative application user.
CVE-2025-40752 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-40820 1 Siemens 16 Sidoor Atd430w, Sidoor Ate530s Coated, Simatic and 13 more 2026-04-15 7.5 High
Affected products do not properly enforce TCP sequence number validation in specific scenarios but accept values within a broad range. This could allow an unauthenticated remote attacker e.g. to interfere with connection setup, potentially leading to a denial of service. The attack succeeds only if an attacker can inject IP packets with spoofed addresses at precisely timed moments, and it affects only TCP-based services.
CVE-2024-22041 1 Siemens 13 Cerberus Pro En Engineering Tool, Cerberus Pro En Fire Panel Fc72x, Cerberus Pro En X200 Cloud Distribution and 10 more 2026-04-15 7.5 High
A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates. This could allow an unauthenticated remote attacker to crash the network service.
CVE-2024-41170 1 Siemens 1 Tecnomatix Plant Simulation 2026-04-15 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0015), Tecnomatix Plant Simulation V2404 (All versions < V2404.0004). The affected applications contain a stack based overflow vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
CVE-2020-28398 1 Siemens 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more 2026-04-15 8.8 High
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The CLI feature in the web interface of affected devices is vulnerable to cross-site request forgery (CSRF). This could allow an attacker to read or modify the device configuration by tricking an authenticated legitimate user into accessing a malicious link.
CVE-2024-52285 1 Siemens 2 Sipass Integrated Ac5102 (acc-g2), Sipass Integrated Acc-ap 2026-04-15 5.3 Medium
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8). Affected devices expose several MQTT URLs without authentication. This could allow an unauthenticated remote attacker to access sensitive data.
CVE-2025-40800 1 Siemens 6 Comos, Nx, Simcenter 3d and 3 more 2026-04-15 7.4 High
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.